-- MIB File: BROCADE-OPTICAL-MONITORING-MIB.mib
-- *********************************************************************
-- BROCADE-OPTICAL-MONITORING-MIB.mib: Extreme Optical Monitoring MIB
--
-- Copyright (c) 2018 Extreme Networks, Inc.
-- All rights reserved.
--
-- *********************************************************************
BROCADE-OPTICAL-MONITORING-MIB DEFINITIONS ::= BEGIN
IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
        FROM SNMPv2-SMI
    MODULE-COMPLIANCE, OBJECT-GROUP        
        FROM SNMPv2-CONF        
	DisplayString, TEXTUAL-CONVENTION
		FROM SNMPv2-TC
    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB
    ifIndex
        FROM IF-MIB
    bcsiModules 
        FROM Brocade-REG-MIB
	;

brocadeOpticalMonitoringMIB  MODULE-IDENTITY
    LAST-UPDATED "201909230000Z" -- Sep 23, 2019
    ORGANIZATION "Extreme Networks, Inc."
    CONTACT-INFO
         "Postal:  Extreme Networks, Inc.
                   6480 Via Del Oro
                   San Jose, CA 95119 USA
          Phone:   +1 408 579-2800
          E-mail:  support@extremenetworks.com
          WWW:     http://www.extremenetworks.com"
    DESCRIPTION
        "This MIB module supports monitoring of port optics 
		 for parameters like, temperature, Tx Power, Rx Power,
		 Tx Bias Current, etc.,."

    REVISION            "201909230000Z" -- Sep 23, 2019
    DESCRIPTION
        "Added bcsiIfMediaInfoTable"
    REVISION    	"201805291200Z" -- May 29, 2018
    DESCRIPTION	
        "Updated ORGANIZATION and CONTACT-INFO with Extreme Networks"
    REVISION        "201611230000Z"
    DESCRIPTION
        "Added support for bcsiOptMonInfoTable."

    REVISION        "201609280000Z"
    DESCRIPTION
        "Initial version of this MIB module."
    ::= { bcsiModules 8 }
    
bcsiOptMonNotifications  OBJECT IDENTIFIER ::=  { brocadeOpticalMonitoringMIB 0 }
bcsiOptMonObjects 		 OBJECT IDENTIFIER ::=  { brocadeOpticalMonitoringMIB 1 }
bcsiOptMonConformance 	 OBJECT IDENTIFIER ::=  { brocadeOpticalMonitoringMIB 2 }

-- Optical Parameters Table per lane for a 40G SR4 and LR4, 
-- 100G LR4 and LR10 optics.

bcsiOptMonLaneTable  OBJECT-TYPE
	 SYNTAX      SEQUENCE OF BcsiOptMonLaneEntry
	 MAX-ACCESS  not-accessible
	 STATUS      current
	 DESCRIPTION
		  "This table lists the instrumented parameters of all
		  lanes within a 40G Optic of type SR4 and LR4,
		  100G optic of type LR4 and LR10. LR4 and SR4 have 4 lanes
		  per optic, LR10 has 10 lanes per optic."
	 REFERENCE
		  "ITU recommendations G.783, G.784, G.953"
	::= { bcsiOptMonObjects 1 }

bcsiOptMonLaneEntry  OBJECT-TYPE
	 SYNTAX      BcsiOptMonLaneEntry
	 MAX-ACCESS  not-accessible
	 STATUS      current
	 DESCRIPTION
		  "Only the ifIndices of optical interfaces
		  whose parameters need to be monitored will
		  be used to index this table."
	 INDEX       { ifIndex, bcsiOptMonLaneNum }
	 ::= { bcsiOptMonLaneTable 1 }

BcsiOptMonLaneEntry ::=
	 SEQUENCE  {
		 bcsiOptMonLaneNum
				  Unsigned32,
		 bcsiOptMonLaneTemperature
				  SnmpAdminString,
		 bcsiOptMonLaneTxPowerStatus
				  INTEGER,
		 bcsiOptMonLaneTxPower
				  SnmpAdminString,
		 bcsiOptMonLaneTxPowerVal
				  Unsigned32,
		 bcsiOptMonLaneRxPowerStatus
				  INTEGER,
		 bcsiOptMonLaneRxPower
				  SnmpAdminString,
		 bcsiOptMonLaneRxPowerVal
				  Unsigned32,
		 bcsiOptMonLaneTxBiasCurrent
				  SnmpAdminString
	 }

bcsiOptMonLaneNum  OBJECT-TYPE
	  SYNTAX    	Unsigned32
	  MAX-ACCESS    not-accessible
	  STATUS    	current
	  DESCRIPTION
		   "The lane number of this 40G or 100G optic.
		    LR4 and SR4 have 4 lanes per optic. 
			LR10 has 10 lanes per optic."
	::= { bcsiOptMonLaneEntry 1 }

bcsiOptMonLaneTemperature  OBJECT-TYPE
	  SYNTAX		SnmpAdminString (SIZE(0..32))
	  MAX-ACCESS    read-only
	  STATUS    	current
	  DESCRIPTION
		   "This object holds the value of the transmitter laser
			diode temperature for the lane in the interface. This
			object indicates the health of the transmitter.

			The format is xxx.yyyy C(elcius), followed by whether
			the measured value is normal, high/low alarm or
			high/low warning."
	::= { bcsiOptMonLaneEntry 2 }

bcsiOptMonLaneTxPowerStatus OBJECT-TYPE
      SYNTAX   INTEGER { 
	  		notSupported(1), 
			notApplicable(2), 
			highAlarm(3), 
			highWarn(4), 
			normal(5), 
			lowWarn(6),  
			lowAlarm(7) 
	  }
	  MAX-ACCESS    read-only
	  STATUS    	current
	  DESCRIPTION
		   "This object holds the status of the transmitter optical
            signal power for the lane in the interface, indicating 
            whether this is normal or an alarm is present."
	 ::= { bcsiOptMonLaneEntry 3 }

bcsiOptMonLaneTxPower  OBJECT-TYPE
	  SYNTAX		SnmpAdminString (SIZE(0..32))
	  MAX-ACCESS    read-only
	  STATUS    	current
	  DESCRIPTION
		   "This object holds the value of the transmitter optical
			signal power for the lane in the interface, measured in
			dBm, followed by whether this is a normal value, or
			high/low warning or alarm."
	 ::= { bcsiOptMonLaneEntry 4 }

bcsiOptMonLaneTxPowerVal  OBJECT-TYPE
	  SYNTAX		Unsigned32
	  UNITS    		"microWatt"
	  MAX-ACCESS    read-only
	  STATUS    	current
	  DESCRIPTION
		   "This object holds the value of the transmitter optical 
            signal power for the lane in the interface, measured in microWatt."
	 ::= { bcsiOptMonLaneEntry 5 }
	 
bcsiOptMonLaneRxPowerStatus OBJECT-TYPE
      SYNTAX   INTEGER { 
	  		notSupported(1), 
			notApplicable(2), 
			highAlarm(3), 
			highWarn(4), 
			normal(5), 
			lowWarn(6),  
			lowAlarm(7)
	  }
	  MAX-ACCESS    read-only
	  STATUS    	current
	  DESCRIPTION
		   "This object holds the status of the receiver optical signal power 
            for the lane in the interface, indicating whether this is normal or
            an alarm is present."
	::= { bcsiOptMonLaneEntry 6 }

bcsiOptMonLaneRxPower  OBJECT-TYPE
	  SYNTAX		SnmpAdminString (SIZE(0..32))
	  MAX-ACCESS    read-only
	  STATUS    	current
	  DESCRIPTION
		   "This object holds the value of the receiver optical
			signal power for the lane in the interface, measured in
			dBm, followed by whether this is a normal value, or
			high/low warning or alarm."
	::= { bcsiOptMonLaneEntry 7 }

bcsiOptMonLaneRxPowerVal OBJECT-TYPE
	  SYNTAX		Unsigned32
      UNITS   		"microWatt"	  
	  MAX-ACCESS    read-only
	  STATUS    	current
	  DESCRIPTION
		   "This object holds the value of the receiver optical signal power
            for the lane in the interface, measured in microWatt."
	::= { bcsiOptMonLaneEntry 8 }

bcsiOptMonLaneTxBiasCurrent  OBJECT-TYPE
	  SYNTAX		SnmpAdminString (SIZE(0..32))
	  MAX-ACCESS    read-only
	  STATUS    	current
	  DESCRIPTION
		   "Tx Bias Current.  It is measured in mA, and is followed
		   by whether this is a normal value, or high/low warning or
		   alarm."
	 ::= { bcsiOptMonLaneEntry 9 }

-- Optical Table for module level optical parameters like Temperature, Tx Power,
-- Rx Power and Tx Bias Current.

bcsiOptMonInfoTable  OBJECT-TYPE
	 SYNTAX      SEQUENCE OF BcsiOptMonInfoEntry
	 MAX-ACCESS      not-accessible
	 STATUS      current
	 DESCRIPTION
		  "This table lists the instrumented parameters of all
		  optical interfaces."
	 REFERENCE
		  "ITU recommendations G.783, G.784, G.953"
	::= { bcsiOptMonObjects 2}

bcsiOptMonInfoEntry  OBJECT-TYPE
	 SYNTAX      BcsiOptMonInfoEntry
	 MAX-ACCESS      not-accessible
	 STATUS      current
	 DESCRIPTION
		  "Only the ifIndices of optical interfaces
		  whose parameters need to be monitored will
		  be used to index this table."
	 INDEX       { ifIndex }
	 ::= { bcsiOptMonInfoTable 1 }

BcsiOptMonInfoEntry ::=
	 SEQUENCE  {
		 bcsiOptMonTemperature
				  DisplayString,
 		 bcsiOptMonTxPowerStatus
				  INTEGER,
		 bcsiOptMonTxPower
				  SnmpAdminString,
		 bcsiOptMonTxPowerVal
				  Unsigned32,
		 bcsiOptMonRxPowerStatus
				  INTEGER,
		 bcsiOptMonRxPower
				  SnmpAdminString,
		 bcsiOptMonRxPowerVal
				  Unsigned32,
 		 bcsiOptMonTxBiasCurrent
 				 DisplayString
}

bcsiOptMonTemperature  OBJECT-TYPE
	  SYNTAX	DisplayString (SIZE(0..32))
  	  MAX-ACCESS    read-only
  	  STATUS    current
  	  DESCRIPTION
   		    "This object holds the value of the transmitter laser
			diode temperature for the interface. This object
			indicates the health of the transmitter.

			The format is xxx.yyyy C(elcius), followed by whether
			the measured value is normal, high/low alarm or
			high/low warning.
			For 100G and 40G optic, this returns the average
			temperature for all lanes."
	::= { bcsiOptMonInfoEntry 1 }

bcsiOptMonTxPowerStatus  OBJECT-TYPE
       SYNTAX   INTEGER {
			notSupported(1), 
			notApplicable(2), 
			highAlarm(3), 
			highWarn(4), 
			normal(5), 
			lowWarn(6), 
			lowAlarm(7)
		}
       	MAX-ACCESS    read-only
       	STATUS    current
       	DESCRIPTION
            "This object holds the status of the transmit optical
			signal power for the interface, indicating whether this is normal or an alarm is present."
     ::= { bcsiOptMonInfoEntry 2 }

bcsiOptMonTxPower  OBJECT-TYPE
	  SYNTAX	DisplayString (SIZE(0..32))
	  MAX-ACCESS    read-only
	  STATUS    current
	  DESCRIPTION
		   "This object holds the value of the transmitter optical
			signal power for the interface, measured in dBm, followed
			by whether this is a normal value, or high/low warning
			or alarm. For 100G optic, this returns the aggregated
			Tx Power for all lanes."
	 ::= { bcsiOptMonInfoEntry 3 }

bcsiOptMonTxPowerVal  OBJECT-TYPE
       	SYNTAX   Unsigned32
       	UNITS    "microWatt"
       	MAX-ACCESS    read-only
       	STATUS    current
       	DESCRIPTION
              		"This object holds the value of the transmitter optical
               signal power for the interface, measured in microWatt.
               For 100G optic, this returns the aggregated 
    	  Tx Power for all lanes "
     ::= { bcsiOptMonInfoEntry 4 }

bcsiOptMonRxPowerStatus  OBJECT-TYPE
       SYNTAX   INTEGER {
			notSupported(1),
			notApplicable(2),
			highAlarm(3),
			highWarn(4),
			normal(5), 
			lowWarn(6),
			lowAlarm(7)
       }
       MAX-ACCESS    read-only
       STATUS    current
       DESCRIPTION
              "This object holds the status of the receiver optical signal
			   power for the interface, indicating whether this is normal or an alarm is present."
     ::= { bcsiOptMonInfoEntry 5 }

bcsiOptMonRxPower  OBJECT-TYPE
	  SYNTAX	DisplayString (SIZE(0..32))
	  MAX-ACCESS    read-only
	  STATUS    current
	  DESCRIPTION
		   "This object holds the value of the receiver optical
			signal power for the interface, measured in dBm, followed
			by whether this is a normal value, or high/low warning
			or alarm.
			For 100G and 40G optic, this returns the aggregated
			Rx Power for all lanes."
	::= { bcsiOptMonInfoEntry 6 }

bcsiOptMonRxPowerVal  OBJECT-TYPE
       	SYNTAX   Unsigned32
       	UNITS   "microWatt"
       	MAX-ACCESS    read-only
       	STATUS    current
       	DESCRIPTION
              		"This object holds the value of the receiver optical
   			 signal power for the interface, measured in microWatt.
   		 For 100G and 40G optic, this returns the aggregated 
    Rx Power for all lanes "
     ::= { bcsiOptMonInfoEntry 7 }

bcsiOptMonTxBiasCurrent  OBJECT-TYPE
	  SYNTAX	DisplayString (SIZE(0..32))
	  MAX-ACCESS    read-only
	  STATUS    current
	  DESCRIPTION
		   "Tx Bias Current.  It is measured in mA, and is followed
		   by whether this is a normal value, or high/low warning or
		   alarm.
		     For 100G and 40G optic, this returns the aggregated
		   Tx Bias Current for all lanes."
	 ::= { bcsiOptMonInfoEntry 8 }

bcsiIfMediaInfoTable OBJECT-TYPE
          SYNTAX      SEQUENCE OF BcsiIfMediaInfoEntry
          MAX-ACCESS  not-accessible
          STATUS      current
          DESCRIPTION
                  "This table lists the information of the media device
		   (SFP/XFP/Copper) installed in the physical port.
		   Only the ifIndices of Ethernet ports those are associated
		   with the operational cards will be included in this table."
          ::= { bcsiOptMonObjects  3 }

bcsiIfMediaInfoEntry OBJECT-TYPE
          SYNTAX      BcsiIfMediaInfoEntry
          MAX-ACCESS  not-accessible
          STATUS      current
          DESCRIPTION
                  "An entry in this table. The ifIndices of ethernet interfaces 
                   will be used to index this table."
          INDEX  { ifIndex } 
          ::= { bcsiIfMediaInfoTable 1 }

BcsiIfMediaInfoEntry ::=
    SEQUENCE  {
          bcsiIfMediaType
                    DisplayString,
          bcsiIfMediaVendorName
                    DisplayString,
          bcsiIfMediaVersion
                    DisplayString,
          bcsiIfMediaPartNumber
                    DisplayString,
          bcsiIfMediaSerialNumber
                    DisplayString
    }

bcsiIfMediaType  OBJECT-TYPE
    SYNTAX       DisplayString (SIZE (0..128))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "he type of the media installed in the physical port."
    ::= { bcsiIfMediaInfoEntry  1 }

bcsiIfMediaVendorName  OBJECT-TYPE
    SYNTAX       DisplayString (SIZE (0..128))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "The media vendor name, full name of the corporation."
    ::= { bcsiIfMediaInfoEntry  2 }

bcsiIfMediaVersion  OBJECT-TYPE
    SYNTAX       DisplayString (SIZE (0..128))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "The media vendor product version number."
    ::= { bcsiIfMediaInfoEntry  3 }

bcsiIfMediaPartNumber OBJECT-TYPE
    SYNTAX       DisplayString (SIZE (0..128))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "The media vendor part number."
    ::= { bcsiIfMediaInfoEntry  4 }

bcsiIfMediaSerialNumber OBJECT-TYPE
    SYNTAX       DisplayString (SIZE (0..128))
    MAX-ACCESS   read-only
    STATUS       current
    DESCRIPTION
            "The vendor serial number of the media device."
    ::= { bcsiIfMediaInfoEntry  5 }
--
-- Conformance
--

bcsiOptMonCompliances OBJECT IDENTIFIER 
                             ::= { bcsiOptMonConformance 1 }
bcsiOptMonGroups       OBJECT IDENTIFIER 
                             ::= { bcsiOptMonConformance 2 }

bcsiOptMonCompliance MODULE-COMPLIANCE
    STATUS     current
    DESCRIPTION
        "The compliance statement for entities which
        implement BROCADE-OPTICAL-MONITORING-MIB."
    MODULE 
		MANDATORY-GROUPS { bcsiOptMonLaneMonGroup ,
				   bcsiOptMonInfoMonGroup,
                                   bcsiIfMediaGroup
						 }
    ::= { bcsiOptMonCompliances 1 }

--
-- Units of Conformance
--
   
bcsiOptMonLaneMonGroup  OBJECT-GROUP
    OBJECTS {
		bcsiOptMonLaneNum,
		bcsiOptMonLaneTemperature,
		bcsiOptMonLaneTxPowerStatus,
		bcsiOptMonLaneTxPower,
		bcsiOptMonLaneTxPowerVal,
		bcsiOptMonLaneRxPowerStatus,
		bcsiOptMonLaneRxPower,
		bcsiOptMonLaneRxPowerVal,
		bcsiOptMonLaneTxBiasCurrent
    }
    STATUS         current  
    DESCRIPTION
        "A collection of objects for Optical Lane Monitoring of interface optics."
    ::= { bcsiOptMonGroups 1 }        

bcsiOptMonInfoMonGroup  OBJECT-GROUP
    OBJECTS {
		bcsiOptMonTemperature,
		bcsiOptMonTxPowerStatus,
		bcsiOptMonTxPower,
		bcsiOptMonTxPowerVal,
		bcsiOptMonRxPowerStatus,
		bcsiOptMonRxPower,
		bcsiOptMonRxPowerVal,
		bcsiOptMonTxBiasCurrent
    }
    STATUS         current  
    DESCRIPTION
        "A collection of objects for Optical Monitoring of interface optics."
    ::= { bcsiOptMonGroups 2 }

bcsiIfMediaGroup  OBJECT-GROUP
    OBJECTS {
                bcsiIfMediaType,
                bcsiIfMediaVendorName,
                bcsiIfMediaVersion,
                bcsiIfMediaPartNumber,
                bcsiIfMediaSerialNumber
    }
    STATUS         current
    DESCRIPTION
        "A collection of objects for monitoring media information of interfaces."
    ::= { bcsiOptMonGroups 3 }
END

-- ========================================================================================