--defines ROOMALERT12E-MIB for SNMP agent extension of Room Alert 12E
--Contents:     Global Registration Module
--              Room Alert OIDs - Enterprise 20916
--Version:      3.3.0
--Date:         28 May 2021
--Developed By: AVTECH Software, Inc.

--
--Copyright (c) 2021 AVTECH Software, Inc.
--

ROOMALERT12E-MIB DEFINITIONS ::= BEGIN


IMPORTS
        enterprises, IpAddress, Counter, TimeTicks
                FROM RFC1155-SMI
        OBJECT-TYPE
                FROM RFC-1212
        TRAP-TYPE
                FROM RFC-1215;


avtech                  OBJECT IDENTIFIER ::= { enterprises 20916 }
products                OBJECT IDENTIFIER ::= { avtech 1 }
roomalert12E    OBJECT IDENTIFIER ::= { products 10 }
sensors                 OBJECT IDENTIFIER ::= { roomalert12E 1 }
lightTower              OBJECT IDENTIFIER ::= { roomalert12E 2 }
internal-sen    OBJECT IDENTIFIER ::= { sensors  1 }
digital-sen1    OBJECT IDENTIFIER ::= { sensors  2 }
digital-sen2    OBJECT IDENTIFIER ::= { sensors  3 }
digital-sen3    OBJECT IDENTIFIER ::= { sensors  4 }
switch1                 OBJECT IDENTIFIER ::= { sensors  5 }
switch2                 OBJECT IDENTIFIER ::= { sensors  6 }
switch3                 OBJECT IDENTIFIER ::= { sensors  7 }
switch4                 OBJECT IDENTIFIER ::= { sensors  8 }
analog                  OBJECT IDENTIFIER ::= { sensors  9 }
relay                   OBJECT IDENTIFIER ::= { sensors 10 }
traps                   OBJECT IDENTIFIER ::= { roomalert12E 3 }

-- Room Alert 12E MIB
-- Parameters




internal-sen-1 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "This value represents the current internal temperature in Celsius"
::= { internal-sen 1 }

internal-sen-2 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "This value represents the current internal temperature in Fahrenheit."
::= { internal-sen 2 }

internal-sen-3 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The internal sensor's label"
::= { internal-sen 3 }

analog-1 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The current status of the Room Alert 12E analog input (0-5VDC)."
::= { analog 1 }

analog-2 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The analog sensor's label."
::= { analog 2 }

analog-3 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The current status of the Room Alert 12E analog input (user-defined scale)."
::= { analog 3 }

relay-1 OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION     "The current status of the Room Alert 12E relay output."
::= { relay 1 }

relay-2 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION "The relay output's label."
::= { relay 2 }

digital-sen1-1 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Celsius."
::= { digital-sen1 1 }

digital-sen1-2 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Fahrenheit."
::= { digital-sen1 2 }

digital-sen1-3 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Temp/Analog sensor, this value represents the current Voltage reading. If this is a Temp/Active Power sensor, this value represents the current power state (1=Power Detected, 0=No Power Detected)."
::= { digital-sen1 3 }

digital-sen1-4 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Temp/Analog sensor, this value represents the current custom reading."
::= { digital-sen1 4 }

digital-sen1-5 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius."
::= { digital-sen1 5 }

digital-sen1-6 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Celsius."
::= { digital-sen1 6 }

digital-sen1-7 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Fahrenheit."
::= { digital-sen1 7 }

digital-sen1-8 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The sensor's label"
::= { digital-sen1 8 }

digital-sen2-1 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Celsius."
::= { digital-sen2 1 }

digital-sen2-2 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Fahrenheit."
::= { digital-sen2 2 }

digital-sen2-3 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Temp/Analog sensor, this value represents the current Voltage reading. If this is a Temp/Active Power sensor, this value represents the current power state (1=Power Detected, 0=No Power Detected)."
::= { digital-sen2 3 }

digital-sen2-4 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Temp/Analog sensor, this value represents the current custom reading."
::= { digital-sen2 4 }

digital-sen2-5 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius."
::= { digital-sen2 5 }

digital-sen2-6 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Celsius."
::= { digital-sen2 6 }

digital-sen2-7 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Fahrenheit."
::= { digital-sen2 7 }

digital-sen2-8 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The sensor's label"
::= { digital-sen2 8 }

digital-sen3-1 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Celsius."
::= { digital-sen3 1 }

digital-sen3-2 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temperature, Temp/Humidity, Temp/Analog, or Temp/Active Power sensor, this value represents the current temperature in Fahrenheit."
::= { digital-sen3 2 }

digital-sen3-3 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current relative humidity in % Relative Humidity. If this sensor is a Temp/Analog sensor, this value represents the current Voltage reading. If this is a Temp/Active Power sensor, this value represents the current power state (1=Power Detected, 0=No Power Detected)."
::= { digital-sen3 3 }

digital-sen3-4 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Fahrenheit. If this sensor is a Temp/Analog sensor, this value represents the current custom reading."
::= { digital-sen3 4 }

digital-sen3-5 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current heat index in Celsius."
::= { digital-sen3 5 }

digital-sen3-6 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Celsius."
::= { digital-sen3 6 }

digital-sen3-7 OBJECT-TYPE
        SYNTAX          INTEGER(0..65535)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "If this sensor is a Temp/Humidity sensor, this value represents the current dew point in Fahrenheit."
::= { digital-sen3 7 }

digital-sen3-8 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The sensor's label"
::= { digital-sen3 8 }

switch-sen1-1 OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The reading for switch sensor 1 (0 = OPEN, 1 = CLOSED)."
::= { switch1 1 }

switch-sen1-2 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The label for switch sensor 1."
::= { switch1 2 }

switch-sen2 OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The reading for switch sensor 2 (0 = OPEN, 1 = CLOSED)."
::= { switch2 1 }

switch-sen2-2 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The label for switch sensor 2."
::= { switch2 2 }

switch-sen3 OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The reading for switch sensor 3 (0 = OPEN, 1 = CLOSED)."
::= { switch3 1 }

switch-sen3-2 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The label for switch sensor 3."
::= { switch3 2 }

switch-sen4 OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The reading for switch sensor 4 (0 = OPEN, 1 = CLOSED)."
::= { switch4 1 }

switch-sen4-2 OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "The label for switch sensor 4."
::= { switch4 2 }

alarmmessage OBJECT-TYPE
        SYNTAX          OCTET STRING
        ACCESS          read-only
        STATUS          mandatory
        DESCRIPTION     "Last Alarm Message"
::= { traps 1 }


-- Light Tower

lightTower-RE OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION     "The status of the red LED on the Light Tower."
::= { lightTower 1 }

lightTower-OR OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION     "The status of the orange LED on the Light Tower."
::= { lightTower 2 }

lightTower-GR OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION     "The status of the green LED on the Light Tower."
::= { lightTower 3 }

lightTower-WH OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION     "The status of the white LED on the Light Tower."
::= { lightTower 4 }

lightTower-BL OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION     "The status of the blue LED on the Light Tower."
::= { lightTower 5 }

lightTower-A1 OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION     "The status of the 1st audio alarm on the Light Tower."
::= { lightTower 6 }

lightTower-A2 OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION     "The status of the 2nd audio alarm on the Light Tower."
::= { lightTower 7 }

lightTower-RL OBJECT-TYPE
        SYNTAX          INTEGER(0..1)
        ACCESS          read-write
        STATUS          mandatory
        DESCRIPTION     "The status of the LTA's on-board relay output"
::= { lightTower 8 }


-- ROOMALERT12E TRAPS

tempalarm1-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A tempalarm1 trap signifies that the current
                        temperature on external sensor 1 is outside the
                        defined high or low threshold."
::= 1

room-alert-12E-snmp-trap TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A room-alert-12E-snmp-trap indicates that an alarm
                        condition has occurred on the sensor inidcated
                        by the alarmMessage variable."
::= 2

tempalarm2-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A tempalarm2 trap signifies that the current
                        temperature on external sensor 2 is outside the
                        defined high or low threshold."
::= 3

tempclear2-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A tempclear2 trap signifies that the current
                        temperature on external sensor 2 has returned to
                        a normal condition and is within the defined
                        high or low threshold."
::= 4

tempalarm3-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A tempalarm3 trap signifies that the current
                        temperature on external sensor 3 is outside the
                        defined high or low threshold."
::= 5

tempclear3-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A tempclear3 trap signifies that the current
                        temperature on external sensor 3 has returned to
                        a normal condition and is within the defined
                        high or low threshold."
::= 6

humidityalarm1-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A humidityalarm1 trap signifies that the current
                        humidity on external sensor 1 is outside the
                        defined high or low threshold."
::= 7

humidityclear1-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A humidityclear1 trap signifies that the current
                        humidity on external sensor 1 has returned to
                        a normal condition and is within the defined
                        high or low threshold."
::= 8

humidityalarm2-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A humidityalarm2 trap signifies that the current
                        humidity on external sensor 2 is outside the
                        defined high or low threshold."
::= 9

humidityclear2-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A humidityclear2 trap signifies that the current
                        humidity on external sensor 2 has returned to
                        a normal condition and is within the defined
                        high or low threshold."
::= 10

humidityalarm3-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A humidityalarm3 trap signifies that the current
                        humidity on external sensor 3 is outside the
                        defined high or low threshold."
::= 11

humidityclear3-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A humidityclear3 trap signifies that the current
                        humidity on external sensor 3 has returned to
                        a normal condition and is within the defined
                        high or low threshold."
::= 12

switchalarm1-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A switchalarm1 trap signifies that switch sensor 1
                        is in an alarm state."
::= 13

switchclear1-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A switchclear1 trap signifies that the switch sensor 1
                        has returned to a normal state."
::= 14

switchalarm2-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A switchalarm2 trap signifies that switch sensor 2
                        is in an alarm state."
::= 15

switchclear2-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A switchclear2 trap signifies that the switch sensor 2
                        has returned to a normal state."
::= 16

switchalarm3-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A switchalarm3 trap signifies that switch sensor 3
                        is in an alarm state."
::= 17

switchclear3-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A switchclear3 trap signifies that the switch sensor 3
                        has returned to a normal state."
::= 18

switchalarm4-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A switchalarm4 trap signifies that switch sensor 4
                        is in an alarm state."
::= 19

switchclear4-12E TRAP-TYPE
        ENTERPRISE      roomalert12E
        VARIABLES       { alarmmessage }
        DESCRIPTION     "A switchclear4 trap signifies that the switch sensor 4
                        has returned to a normal state."
::= 20
END