--  SIAE MICROELETTRONICA s.p.a.
--                 
--  Via Michelangelo Buonarroti, 21
--  20093 - Cologno Monzese
--  Milano 
--  ITALY
--
-- ----------------------------------------------------------------------------
-- ----------------------------------------------------------------------------

SIAE-ACM-STATISTICS-MIB
        DEFINITIONS ::= BEGIN

        IMPORTS
             MODULE-IDENTITY, OBJECT-TYPE,
             Counter32, Integer32, Unsigned32
        FROM SNMPv2-SMI
             TEXTUAL-CONVENTION,
             DisplayString, RowStatus
        FROM SNMPv2-TC
             siaeMib
        FROM SIAE-TREE-MIB
             AlarmStatus, AlarmSeverityCode
        FROM SIAE-ALARM-MIB;

    acmStats MODULE-IDENTITY
        LAST-UPDATED "201411050000Z"
        ORGANIZATION "SIAE MICROELETTRONICA spa"
        CONTACT-INFO
            "SIAE MICROELETTONICA s.p.a.
             Via Michelangelo Buonarroti, 21
             20093 - Cologno Monzese
             Milano - ITALY
             Phone :  +39-02-27325-1
             E-mail: tbd@siaemic.com
            "
        DESCRIPTION
            "Adaptive Code Modulation (ACM) Statistics (Performance Monitoring)
            "
        REVISION "201411050000Z"
        DESCRIPTION 
            "MIB version 01.00.01
             - Added ACM profilea 4096 QAM and 4096QAM strong
              (changed AcmProfile TEXTUAL-CONVENTION)
            "
        REVISION "201402110000Z"
        DESCRIPTION 
            "Initial version 01.00.00
            "
    ::= { siaeMib 75 }

----------------------------------------------------------------------------------
--  Textual Conventions
----------------------------------------------------------------------------------

     AcmProfile ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
         "List of supported ACM profiles.
         "
       SYNTAX INTEGER {
              unavailable         (1),  -- This is a virtual profile needed to
                                        -- create a row in the table of counters
                                        -- in order to count seconds with modem
                                        -- not locked.
              downshift           (2),  -- This is a virtual profile needed to
                                        -- create a row in the table of counters
                                        -- in order to count transitions towards
                                        -- lower profiles. 
              upshift             (3),  -- This is a virtual profile needed to
                                        -- create a row in the table of counters
                                        -- in order to count transitions towards 
                                        -- upper profiles.
              acmBPSKstrong       (4),
              acmBPSK             (5),
              acm4QAMstrong       (6),
              acm4QAM             (7),
              acm8PSKstrong       (8),
              acm8PSK             (9),
              acm16QAMstrong      (10),
              acm16QAM            (11),
              acm32QAMstrong      (12),
              acm32QAM            (13),
              acm64QAMstrong      (14),
              acm64QAM            (15),
              acm128QAMstrong     (16),
              acm128QAM           (17),
              acm256QAMstrong     (18),
              acm256QAM           (19),
              acm512QAMstrong     (20),
              acm512QAM           (21),
              acm1024QAMstrong    (22),
              acm1024QAM          (23),
              acm2048QAMstrong    (24),
              acm2048QAM          (25),
              acm4096QAMstrong    (26),
              acm4096QAM          (27)
         }

----------------------------------------------------------------------------------
--  object identifier inside the module
----------------------------------------------------------------------------------

----------------------------------------------------------------------------------
--  acmStats (PERFORMANCE MONITORING ACM) Group
----------------------------------------------------------------------------------
--
--  The following objects are used to manage the ACM counters.
--  The  objects of this group are meaningful only if radioEquipAcmEngineEnable
--  is equal to "enable".
--
----------------------------------------------------------------------------------

------ Beginning --------------------------------------------------------------

    acmsMibVersion  OBJECT-TYPE
        SYNTAX      INTEGER
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Numerical version of this module.
             The string version of this MIB have the following format:
                XX.YY.ZZ
             so, for example, the value 1 should be interpreted as 00.00.01
             and the value 10001 should be interpreted as 01.00.01."
    ::= {acmStats 1}

--
--  TERMINATION POINT LINK TABLE
--

--
-------  The following table contains the records used to manage the P.M.

-------  Begin of acmsTpLinkTable
--
    acmsTpLinkTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF AcmsTpLinkRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with ACM Termination Point of the radio links.
             This table contains object to activate and deactivate the
             buildup of counters.
            "
    ::= {acmStats 2}

    acmsTpLinkRecord  OBJECT-TYPE
        SYNTAX      AcmsTpLinkRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Entry of acmsTpLinkTable.
            "
        INDEX {acmsTpLinkId, acmsTpLinkPolId}
    ::= {acmsTpLinkTable 1}

    AcmsTpLinkRecord  ::=
        SEQUENCE    {
            acmsTpLinkId         Integer32,
            acmsTpLinkPolId      Integer32,
            acmsTpLinkStartStop  INTEGER,
            acmsTpLinkLabel      DisplayString,
            acmsTpLinkRowStatus  RowStatus
        }

    acmsTpLinkId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This object identifies the Radio link.
            "
    ::= {acmsTpLinkRecord 1}

    acmsTpLinkPolId  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This object identifies the Radio link polarization for XPIC
             configuration. In non XPIC link this object should be 1.
            "
    ::= {acmsTpLinkRecord 2}

    acmsTpLinkStartStop  OBJECT-TYPE
        SYNTAX      INTEGER {
                             start   (1),
                             stop    (2)
                            }
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "This object is used to start and to stop the statistic 
             (Perfomance Monitoring) counter evaluation.
            "
        DEFVAL {stop}
    ::= {acmsTpLinkRecord 3}

    acmsTpLinkLabel  OBJECT-TYPE
        SYNTAX      DisplayString   (SIZE(0..31))
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "ASCII string used to identify the ACM Termination Point.
            "
    ::= {acmsTpLinkRecord 4}

    acmsTpLinkRowStatus   OBJECT-TYPE 
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Status of this row of acmsTpLinkTable.

             When set to notInService, associated acmsTpProfileTable
             rows may be added, deleted and modified.

             When an attempt is made to set acmsTpLinkRowStatus to
             active, there is at least a row in acmsTpProfileTable with
             first index equal to acmsTpLinkId. Otherwise, the error
             inconsistentValue is returned to the set attempt.

             The creation of a row in this table, creates a row with the
             same index in of acmsTpMaintTable.

             The deletion of a row in this table, deletes a row with the
             same index in of acmsTpMaintTable.

             If this object is set to destroy, must not be no rows in 
             acmsTpProfileTable associated by acmsTpLinkId to the row
             that is being deleted, otherwise, the error inconsistentValue
             is returned to the set attempt. Hence, profile instances must
             be deleted before this link instance.
            "
    ::= {acmsTpLinkRecord 5}

--
-------   End of acmsTpLinkTable

--
--  PROFILE TABLE
--

-------  Begin of acmsTpProfileTable
--
    acmsTpProfileTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF AcmsTpProfileRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "ACM Termination Point Thresholds Class table.
             Table with AcmsTpProfileRecord records.
             This table contains alarms and related thresholds to notify them
             within a specific time interval. 
            "
    ::= {acmStats 3}

    acmsTpProfileRecord  OBJECT-TYPE
        SYNTAX      AcmsTpProfileRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Entry of acmsTpLinkTable.
             Several instances (a instance for each ACM profile supported by
             the radio system) of this record is created on creation of
             acmsTpLinkTable.
            "
        INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsTpProfileId}
    ::= {acmsTpProfileTable 1}

    AcmsTpProfileRecord  ::=
        SEQUENCE    {
            acmsTpProfileId            AcmProfile,
            acmsTpProfile15mAlarm      AlarmStatus,
            acmsTpProfile24hAlarm      AlarmStatus,
            acmsTpProfile15mThreshold  Integer32,
            acmsTpProfile24hThreshold  Integer32,
            acmsTpProfileRowStatus     RowStatus
        }

    acmsTpProfileId  OBJECT-TYPE
        SYNTAX      AcmProfile
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This object identifies the ACM profile of the radio system.
            "
    ::= {acmsTpProfileRecord 1}

    acmsTpProfile15mAlarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "If acmsCounteValue crosses the threshold acmsTpProfile15mThreshold,
             this alarm is notified.
            "
    ::= {acmsTpProfileRecord 2}

    acmsTpProfile24hAlarm  OBJECT-TYPE
        SYNTAX      AlarmStatus
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "If acmsCounteValue crosses the threshold acmsTpProfile24hThreshold,
             this alarm is notified.
            "
    ::= {acmsTpProfileRecord 3}

    acmsTpProfile15mThreshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a 15 minutes interval to set 
             acmsTpProfile15mAlarm. The special value 0 turn off the alarm.

             For downshift and upshift profiles, this threshold reports
             the number of times a profile must be changed within a 15 minutes
             interval to set acmsTpProfile15mAlarm.
            "
    ::= {acmsTpProfileRecord 4}

    acmsTpProfile24hThreshold  OBJECT-TYPE
        SYNTAX      Integer32
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Number of seconds within a 24 hours interval to set 
             acmsTpProfile24hAlarm. The special value 0 turn off the alarm.

             For the profiles downshift and upshift, this threshold reports
             the number of times a profile must be changed within a 24 hours
             interval to set acmsTpProfile24hAlarm.
            "
    ::= {acmsTpProfileRecord 5}

    acmsTpProfileRowStatus   OBJECT-TYPE 
        SYNTAX      RowStatus
        MAX-ACCESS  read-create
        STATUS      current
        DESCRIPTION
            "Status of this row of acmsTpProfileTable.

             A row in the acmsTpProfileTable may not be created,
             deleted, set to notInService or otherwise modified
             if the there is no a row in acmsTpProfileTable with the 
             same acmsTpLinkId and the associated acmsTpLinkRowStatus
             object is equal to active. However, if the acmsTpLinkRowStatus
             object is equal to notInService, a row may be created, deleted
             or modified. In other words, a profile may not be added,
             deleted or modified if the ACM statistics of a radio link
             is active.

             The creation on a row in this table, creates a row with the same
             index in of acmsProfileCounterTable.

             If this object is set to destroy, the associated instance
             of acmsProfileCounterTable will also be deleted by this action.
            "
    ::= {acmsTpProfileRecord 6}

--
--  MAINTENANCE TABLE
--

-------  Begin of acmsTpMaintTable
--
    acmsTpMaintTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF AcmsTpMaintRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with Command for maintenance of Termination Point.
             Objects in this table is not persistent.
            "
    ::= {acmStats 4}

    acmsTpMaintRecord  OBJECT-TYPE
        SYNTAX      AcmsTpMaintRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "ACM Termination Point Maintenance record.
             An Instance of this record is created on creation of
             acmsTpLinkTable.
            "
        INDEX {acmsTpLinkId, acmsTpLinkPolId}
    ::= {acmsTpMaintTable 1}

    AcmsTpMaintRecord  ::=
        SEQUENCE    {
            acmsTpMaintCounterClear INTEGER,
            acmsTpMaintAlarmClear   INTEGER
        }

    acmsTpMaintCounterClear  OBJECT-TYPE
        SYNTAX      INTEGER {
                             notActive   (0),
                             clear       (1)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object is used to clear the statistic (Perfomance Monitoring)
             counters.
            "
    ::= {acmsTpMaintRecord 1}

    acmsTpMaintAlarmClear  OBJECT-TYPE
        SYNTAX      INTEGER {
                             notActive   (0),
                             clear       (1)
                            }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object is used to clear the threshold cross alarms.
            "
    ::= {acmsTpMaintRecord 2}
--
-------  End of acmsTpMaintTable

--
--  COUNTERS TABLE
--

-------  Begin of acmsBlockTable
--
    acmsIntervalTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF AcmsIntervalRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with records of block.
            "
    ::= {acmStats 5}

    acmsIntervalRecord  OBJECT-TYPE
        SYNTAX      AcmsIntervalRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Entry of acmsBlockTable.
             There is an entry in acmsBlockTable for each radio link.
             Several (up to 19) instances of this record are created since
             the first time that acmsTpLinkStartStop becomes start.
            "
        INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsIntervalId}
    ::= {acmsIntervalTable 1}

    AcmsIntervalRecord  ::=
        SEQUENCE    {
            acmsIntervalId        INTEGER,
            acmsIntervalType      INTEGER,
            acmsIntervalStatus    INTEGER,
            acmsIntervalTimeStamp Unsigned32
        }

    acmsIntervalId  OBJECT-TYPE
        SYNTAX      INTEGER (1..19)
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "This object identifies time intervals according to the
             following code:

             (1)   Current Daily counters
             (2)   Daily counters of the day before
             (3)   Current a day counters
             (4)   a day interval N. 1
                   (The most recently completed 15 minute interval)
             ...

             (19)  a day interval N. 16
                   (The oldest day counters - 4 hours ago).

             The interval identified by 4 is the most recently completed 15
             minute interval, and the interval identified by N is the interval
             immediately preceding the one identified by N-1.
            "
    ::= {acmsIntervalRecord 1}

    acmsIntervalType  OBJECT-TYPE
        SYNTAX      INTEGER {
                             daily       (1),
                             fifteen-min (2)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The type of the counter interval: it can describe a daily block
             counter or a counter related to a 15 minutes interval.
            "
    ::= {acmsIntervalRecord 2}

    acmsIntervalStatus  OBJECT-TYPE
        SYNTAX      INTEGER {
                             meaningless   (1),
                             meaningfull   (2),
                             incomplete    (3),
                             dummy         (4),
                             lost          (5),
                             restarted     (6)
                            }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Interval status.
            "
    ::= {acmsIntervalRecord 3}

    acmsIntervalTimeStamp  OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "The object is the time when the performance record is closed.
             The time is shown as the number of seconds since January 1, 1970
            "
    ::= {acmsIntervalRecord 4}

--
-------  End of acmsLinkBlockTable
-------  The following table contains the records with the counters used to monitor
-------  the ACM profile (modulation) active on the transmitted frame

-------  Begin of acmsProfileCounterTable
--
    acmsProfileCounterTable  OBJECT-TYPE
        SYNTAX      SEQUENCE OF AcmsCounterRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Table with records of ACM statistics counters.
            "
    ::= {acmStats 6}

    acmsProfileCounterRecord  OBJECT-TYPE
        SYNTAX      AcmsCounterRecord
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "Entry of acmsProfileCounterTable.
             There is an entry in acmsProfileCounterTable for each profile
             of each radio link.
             Several (up to 19) instances of this record are created since
             the first time that acmsTpLinkStartStop becomes start.
            "
        INDEX {acmsTpLinkId, acmsTpLinkPolId, acmsTpProfileId, acmsIntervalId}
    ::= {acmsProfileCounterTable 1}

    AcmsCounterRecord  ::=
        SEQUENCE    {
            acmsProfileCounterValue          Counter32
        }

    acmsProfileCounterValue  OBJECT-TYPE
        SYNTAX      Counter32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "When index acmsTpProfileId is downshift, this object counts the
             number of times that the active profile is moved to a lower one.
  
             When index acmsTpProfileId is upshift, this object counts the
             number of times that the active profile is moved to an upper one.
             
             When index acmsTpProfileId is unavailable, this object counts
             the number of seconds in which the modem is not locked.
             
             For all other values of acmsTpProfileId the object counts the
             number of seconds for which the rx profile relative to this row
             of the table has been active.
            "
    ::= {acmsProfileCounterRecord 1}

--
-------  End of acmsProfileCounterTable

--
-------  The following objects are common to all radio branches.
--

    acmsTpProfile15mAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the acmsTpProfile15mAlarm
             and enables/disables the trap generation on status change event.
            "
        DEFVAL {majorTrapEnable}
    ::= {acmStats 7}

    acmsTpProfile24hAlarmSeverityCode  OBJECT-TYPE
        SYNTAX      AlarmSeverityCode
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "Define the severity associated to the acmsTpProfile24hAlarm
             and enables/disables the trap generation on status change event.
            "
        DEFVAL {majorTrapEnable}
    ::= {acmStats 8}

------ End group -----------------------------------------------------------------

END